The Ruo protection of air source heat pump water heater to reach the maximum results?

2013-9-5 read:1967

The heat exchanger such as long work to use, the plates will be sure the build-up on scaling affect the heat transfer results, and thus subject to periodical cleaning. Plain status from time to collapse the cleaning water out of the debris tendency to scour the anti-media activity, but the pressure shall not exceed the obligations of pressure, can also be used for aggressive chemical cleaning agent for stainless steel. What, then do not open can not be useful for cleaning the heat exchanger equipment, demand for removable and washable, removable and washable when the collapse of the heat exchanger with a brown brush to wash the the plate appearance dirt, can also be used non-aggressive chemical cleaning agents to wash. May not pay attention to with a metal brush to wash, so as not to damage the plate of anticorrosive abilities.

Plate tectonic heat exchanger plate heat exchanger units during washable according certainly the one by one apart, loosen the bolts on superficial heat exchanger: serious according to the drawing process by one by one after the collapse of the cleaning one by one bolt to use the technology (ie, equal to 1.5 times the bolt of the bolts and bolts, and grow the local are thread diameter and positioning bolts and bolts, as the processing by the user). Assembly pressed, and then put the bolts average compression does not leak, and pressed a size not less than the size of A.

Hanging heat exchanger, loosen the bolt movement pressing plate to the bracket at one end removed. Each plate and remove the distinction between washing as it was installed back pressed to not leak. The heat exchangers use certainly work, if loose leak can then average the bolts do not leak, but if pressed to less than the size of A or gasket aging, is necessary to change the gasket.

Change the way of heat exchanger gaskets, pull down the old gasket seal tank residue left over glue, washing clean, monotonous, soaked with gasoline, and then in the tank and seals the opposite thin, coated with a layer of 801 glue will seal embedded in the slot, pressed around the average, 72 hours before the new assembly to use.